ETi® 400 HIGH EFFICIENCY HEATER - INSTALLATION AND USER’S GUIDE
Download Manual in English
Download Manual in French
Download Manual in Spanish
Warning and Safety Information | 5 |
Important Notices | 5 |
Heater Application Information | 5 |
Code Requirements | 6 |
Consumer Information and Safety Information | 6-8 |
Heater Identification Information | 9 |
Section 1. Operation Instructions | 10 |
Operator Control Panel | 10-11 |
Basic System Operation | 11 |
Heater DSI Electronic Ignition Lighting/Operation | 11 |
Start-Up Operation | 12 |
Putting the Heater Into Service | 12 |
Heater Operating Instructions | 13 |
To Turn Off Gas to the Appliance | 13 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety Controls (Air Flow Switches, Water Pressure Switches, High Limit Shut-Off Switches) | 14-15 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ignition Module Operation | 15 |
Section 2. Installation | 16 |
Heater Description | 16 |
Putting the Heater into Service | 16 |
Sequence Of Operation | 17 |
Specifications | 17-18 |
Plumbing Connections | 19 |
Water Connections | 19 |
Valves | 20 |
Manual By-Pass | 20 |
Below Pool Installation | 20 |
Gas Connections | 21 |
Gas Pipe Sizing | 21 |
Gas Pressure Testing | 22 |
Checking Gas Pressure Through Gas Control Valve | 22 |
Sediment Traps | 23 |
Outdoor Installation (US and Canada) | 24-26 |
Outdoor Installation Venting Guidelines | 27 |
Heater Clearances - Outdoor | 27 |
Indoor Venting — General Requirements (Category IV Vertical and Horizontal requirements) | 27 |
Heater Clearances — General Requirements (Indoor and Outdoor Installation for US and Canada) | 27 |
Direct Air Intake Cover | 27 |
Combustion Air Supply | 28 |
Air Supply Requirements Guide for the ETi 400 Heater | 28 |
Direct Air Intake Exhaust Duct using 4-inch PVC Pipe (Indoor Installation) | 29-35 |
Direct Air Intake Kit Installation (Combustion Air Supply) | 30 |
Corrosive Vapors and Possible Causes | 31 |
Horizontal or Vertical Venting (Category IV) - Positive Pressure | 32 |
Vent Installation (Indoor Installation for U.S. or Outdoor Shelter for Canada) | 33 |
Direct Vent Requirements | 33-34 |
Direct Vent - Horizontal Through- the-Wall (Termination) | 35 |
Vent Installation - Indoor Installation (US and Canada) | 35 |
Garage or Utility Room Installation (Vent Installation - Indoor Installation US and Canada) | 36 |
Final Installation Check | 36 |
Condensate Management (Maintenance, Condensate Neutralizer Cartridge Drain/Tubing Installation) | 37 |
Electrical Connections | 38 |
Bonding | 38 |
120 VAC/240 VAC Wiring | 39 |
Remote Control Connections | 40 |
Fireman's Switch Connection | 31 |
Heater Connection Wiring Diagram Causes | 41 |
Heater Ladder Wiring Diagram | 42 |
Section 3. Troubleshooting | 43 |
Initial Troubleshooting and Error / Fault Codes | 43 |
Initial Troubleshooting Chart | 5 |
Code Requirements | 44 |
Heater Will Not Fire A | 45 |
Heater Will Not Fire B | 46 |
Diagnostics LEDs: PS, HLS, TF, IGN, AFS, AG1, AG2, FS | 47-51 |
Burner Troubleshooting | 52 |
Heat Exchanger Troubleshooting | 52 |
Operator Control Panel Displays RNC Code | 52 |
Section 4. Maintenance and Care Instruction | 53 |
Care and Maintenance | 53 |
TitanTough Heat Exchanger Assemblies Annual Inspection | 53 |
Burner Spark Electrode and Flame Sensor Rod Annual Inspection | 54 |
Pressure Relief Valve (50 psi) | 54 |
After Start-Up | 55 |
Spring and Autumn | 55 |
Winter Operation and Winterization | 55 |
Return the Heater to Service | 56 |
Maintaining Pool Temperature | 56 |
Energy Saving Tips | 56 |
Chemical Balance | 57-58 |
Section 5. Heater Replacement Parts | 59-65 |
Heater Replacement Parts List | 60 |
General Replacement Parts List | 60 |
Heater Heat Exchanger and Blower Assemblies Replacement Parts | 63 |
Heater Manifold Assembly - Inlet and Outlet Assembly Replacement Parts | 63 |
Heater Condensate and Exhaust Assembly Replacement Parts | 64 |
Heater Operator Control Panel Assembly Replacement Parts | 65 |